Nigerian Medical Journal

ORIGINAL ARTICLE
Year
: 2016  |  Volume : 57  |  Issue : 6  |  Page : 339--346

Quality of acute asthma care in two tertiary hospitals in a state in South Western Nigeria: A report of clinical audit


Olufemi Olumuyiwa Desalu1, Adekunle Olatayo Adeoti2, Olarinde Jeffrey Ogunmola3, Joseph Olusesan Fadare4, Tolutope Fasanmi Kolawole3 
1 Department of Medicine, University of Ilorin Teaching Hospital, Ilorin, Nigeria
2 Department of Medicine, Ekiti State University Teaching Hospital, Ado-Ekiti, Nigeria
3 Department of Medicine, Federal Teaching Hospital, Ido-Ekiti, Nigeria
4 Department of Pharmacology, Ekiti State University Teaching Hospital, Ado-Ekiti, Nigeria

Correspondence Address:
Olufemi Olumuyiwa Desalu
Department of Medicine, University of Ilorin Teaching Hospital, PMB 1459, Ilorin, Kwara State
Nigeria

Background: To audit the quality of acute asthma care in two tertiary hospitals in a state in the southwestern region of Nigeria and to compare the clinical practice against the recommendations of the Global Initiative for Asthma (GINA) guideline. Patients and Methods: We carried out a retrospective analysis of 101 patients who presented with acute exacerbation of asthma to the hospital between November 2010 and October 2015. Results: Majority of the cases were females (66.3%), <45 years of age (60.4%), and admitted in the wet season (64.4%). The median duration of hospital stay was 2 days (interquartile range; 1-3 days) and the mortality was 1.0%. At admission, 73 (72.3%) patients had their triggering factors documented and 33 (32.7%) had their severity assessed. Smoking status, medication adherence, serial oxygen saturation, and peak expiratory flow rate measurement were documented in less than half of the cases, respectively. Seventy-six (75.2%) patients had nebulized salbutamol, 89 (88.1%) had systemic corticosteroid, and 78 (77.2%) had within 1 h. On discharge, 68 (67.3%) patients were given follow-up appointment and 32 (31.7%) were reviewed within 30 days after discharge. Less than half were prescribed an inhaled corticosteroid (ICS), a self-management plan, or had their inhaler technique reviewed or controller medications adjusted. Overall, adherence to the GINA guideline was not satisfactory and was very poor among the medical officers. Conclusion: The quality of acute asthma care in our setting is not satisfactory, and there is a low level of compliance with most recommendations of asthma guidelines. This audit has implicated the need to address the non-performing areas and organizational issues to improve the quality of care.


How to cite this article:
Desalu OO, Adeoti AO, Ogunmola OJ, Fadare JO, Kolawole TF. Quality of acute asthma care in two tertiary hospitals in a state in South Western Nigeria: A report of clinical audit.Niger Med J 2016;57:339-346


How to cite this URL:
Desalu OO, Adeoti AO, Ogunmola OJ, Fadare JO, Kolawole TF. Quality of acute asthma care in two tertiary hospitals in a state in South Western Nigeria: A report of clinical audit. Niger Med J [serial online] 2016 [cited 2024 Mar 28 ];57:339-346
Available from: https://www.nigeriamedj.com/article.asp?issn=0300-1652;year=2016;volume=57;issue=6;spage=339;epage=346;aulast=Desalu;type=0