Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
Users Online: 35629

 

Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Advertise Contacts Login 
     

  Table of Contents  
ORIGINAL ARTICLE
Year : 2014  |  Volume : 55  |  Issue : 4  |  Page : 333-337  

Early outcome of incisional hernia repair using polypropylene mesh: A preliminary report


1 Department of Surgery, University of UyoTeaching Hospital, Uyo, Nigeria
2 Department of Obstetrics and Gynaecology, University of UyoTeaching Hospital, Uyo, Nigeria

Date of Web Publication21-Jul-2014

Correspondence Address:
Isaac A Udo
Department of Surgery, University of Uyo Teaching Hospital, Uyo
Nigeria
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0300-1652.137197

Rights and Permissions
   Abstract 

Background: The use of prosthetics for open repair of incisional hernia is very recent in our practice. We highlight our experience repairing incisional hernias with polypropylene mesh. Patients and Methods: Patients presenting with incisional hernia >5 cm in length or width received open polypropylene mesh repair and were followed for two years. Data obtained included age, sex, primary surgery causing the hernia, the length of the fascial defect and previous attempts at repair. Post-operative wound complications were recorded. The integrity of the scar and patient satisfaction or concerns with the repair was assessed at each visit. Results: Nineteen females with a mean age of 35 years (range 30-54) underwent repair; most arising from obstetric or gynaecological procedures. Sixteen (82.2%) had midline, 2 (10.5) transverse and 1 (5.3) Pfannenstiel scars. One patient had no previous repair (R0), 7 had undergone one repair (R1), 9 had undergone two repairs (R2) and 1 had three previous repairs (R3). The length of fascial defects ranged from 8 to 18 cm and seroma collection and stitch sinus were the common problems encountered. Two (10.5%) recurrences were recorded in two years. Conclusion: Open mesh repair of incisional hernia carries a low risk of infection and recurrence in two years.

Keywords: Incisional hernia, low recurrence, polypropylene mesh, seroma


How to cite this article:
Udo IA, Bassey EA, Abasiattai AM. Early outcome of incisional hernia repair using polypropylene mesh: A preliminary report. Niger Med J 2014;55:333-7

How to cite this URL:
Udo IA, Bassey EA, Abasiattai AM. Early outcome of incisional hernia repair using polypropylene mesh: A preliminary report. Niger Med J [serial online] 2014 [cited 2024 Mar 29];55:333-7. Available from: https://www.nigeriamedj.com/text.asp?2014/55/4/333/137197


   Introduction Top


Incisional hernia is increasingly adding to the workload of the general surgeon in our practice and presents enormous operative challenges on account of difficult scar tissue and extensive adhesions encountered. These hernias follow previous abdominal wall surgery and are common with midline incisions and, rarely, laparoscopic port [1] sites or ambulatory peritoneal dialysis cannula sites. [2]

Incisional hernias occur in approximately 5% to 15% of laparotomies [3],[4] and become apparent within the first five years; [5] but could take as long as 15 years to manifest. [6] Poor surgical technique and post operative wound infection are contributory. Midline scars are particularly vulnerable because of the poor healing properties of fascial tissue. [1],[4] Obesity, size of defect, [7] advanced age, prolonged use of steroids, malnutrition, uraemia, diabetes, jaundice and raised intra-abdominal pressure from any cause are other known risk factors. [4],[8],[9]

Long term recurrence is a parameter of interest for incisional hernia repairs. [10] Open suture repair is popular in resource-poor settings due partly to non-availability or cost of mesh. Some workers report low clinical recurrence with this repair [11],[12] but ultrasound detected evidence of recurrence may be higher. [13] Suture repairs for hernia defects exceeding 5 cm length is associated with recurrence as high as 43% because of raised intra-abdominal pressures which causes the sutures to cut through the fascia. [3],[7] Open prosthetic repair of large hernias, in particular recurrent incisional hernias, is documented to be tension-free with reduced recurrence.


   Patients and methods Top


This is a prospective investigator-driven observational study of adults presenting to a general surgery clinic with incisional hernias.

Incisional hernia with fascial defects exceeding 4cm in length or width were included from the study.

Incisional hernia with fascial defects less than 4 cm, presence of obstructive and strangulating symptoms or co-morbidities which preclude general anaesthesia, intra-abdominal masses or chronic cough were excluded from the study.

Approval for ethical clearance was obtained from the local institutional Ethical Review Board.

All patients satisfying the inclusion criteria underwent detailed abdominal, cardiovascular and respiratory examinations and did a minimum of full blood count, chest X-ray and urine analysis. The processes of mesh insertion and its possible post-operative complications were fully explained to each patient by the lead surgeon. Patients who were pregnant at presentation were scheduled for operative delivery at term by the obstetrician and hernia repair done concurrently. Consent was obtained from patients for an open repair using polypropylene mesh (PROLENE* Mesh, ETHICON Inc.) under general anaesthesia with endotracheal intubation. All patients received subcutaneous enoxaparim for venous thrombo-embolism prophylaxis pre- and post-operatively and 1g of intravenous ceftriazone at induction of anaesthesia.

The previous abdominal scar was carefully excised through an elliptical incision, with extensive dissection of the subcutaneous tissue to define the fascial margins. The peritoneum was routinely opened and adhesions, where present, lysed and redundant peritoneum excised. The fascial defect was clearly identified and its length measured. The medial border of the rectus sheath was opened and the posterior aspect was closed with Vicryl 1 while the anterior sheath was closed with nylon 1. Polypropylene mesh was then shaped and placed on the fascia as an on-lay with an overlap of 3-5 cm from the midline and fixed in position with nylon 3.0 suture. The anterior rectus sheath was not closed if doing so produced tension; in such instance the mesh was used to bridge the defect. A vacuum drain was placed through a stab in the wound and for 72 hours and effluent measured. Skin sutures were removed on the tenth day.

All the patients were followed-up for two years; initially at three-monthly intervals for nine months in the clinic and subsequently by six-monthly phone calls. Those who had complaints were asked to return to clinic for re-evaluation.

Data obtained included patient age, sex, primary surgery that produced the hernia, the length of the fascial defect and the number of previous attempts at repair. Post-operative wound seroma, stitch abscess and wound infection was recorded. The integrity of the scar and patient satisfaction with the repair was assessed at two years.

Data analysis

Data obtained was analyzed with Statistical Package for Social Sciences 17 for Windows (SPSS Inc. Chicago, IL) and presented as mean, simple percentages and tables.


   Results Top


Nineteen females with a mean age of 35 years (range 30-65) underwent open incisional hernia repairs with polypropylene mesh [Table 1]. Nine (47.3%) were in the 30-39year age group; 14 (73.6%) arose from Caesarean sections and midline incisions were employed in 17 (89.4%). All the initiating operations, excepting in one case, were done at secondary or private health facilities, and 17 patients (89.4%) had previously attempted suture repair of the hernias which failed [Figure 1] and [Figure 2]. Seroma collection and stitch sinus were the primary complications observed; none progressed to develop wound infection. Two recurrences (10.5%) occurred in two years. The commonest concern of the patients was the long term effect of the presence of the mesh in their abdominal wall and its implications for subsequent pregnancies and surgery. All were satisfied with the outcome at two years.
Figure 1: A young female presenting with multiple fascial defects and an ugly scar from three previous suture repairs of incisional hernia

Click here to view
Figure 2: Same patient in Figure 1 six months after receiving open polypropylene mesh repair

Click here to view
Table 1: Incisional hernias are common among young females receiving midline incisions for obstetrics or gynecological procedures and recurrence is frequent after suture repairs

Click here to view



   Discussion Top


Incisional hernia is a common complication of abdominal operations and its prevalence closely reflects the number and extent of abdominal procedures done in a locality. [14] The prevalence of this condition in our practice is unknown but observation in our out-patient clinic would suggest the condition is common among young women who have had abdominal surgeries. In the US incisional hernia constitutes 9% of 1 million abdominal wall hernias repaired annually. [15] Only a few in our practice seek medical advice and fewer still procure a repair; perhaps, because of cost or frustration from previous failed repairs.

Failed technique is strongly associated with initiating the events that culminate in wound failure and subsequent hernia formation. In particular, use of absorbable sutures to close fascia, closing the abdomen under tension, passing a drain through the wound and wound infection are critical to hernia formation. Most incisional hernias in our practice arise from gynaecological or obstetrics procedures; these are common among females in the reproductive age group, similar to reports by Agbakwuru and Pilay [16] et al., in Ife South-West Nigeria. It would therefore appear incisional hernia is a disease of females in Nigeria, similar to findings by Memon [17] and Pavan. [18] However, the gynaecologic or obstetric nature of the primary operations could not be strongly implicated as predisposing factors; rather factors like technical execution of the procedures, type of closure and wound infection need be considered.

Incisional hernia is a surgeon dependent variable and the techniques involved in the primary surgery, repair of hernia or recurrence plays a major role in re-herniation. We could not verify the experience of the surgeons performing the primary procedures but we are aware most practitioners at secondary and private care are not gynaecologists or obstetricians. Midline incisions are preferred in many gynaecological and obstetric procedures because it is technically simple and fast to execute. The resulting wounds, however, heal poorly because of low vascularity of fascia, forming weak scars which easily fail. Sub-umblical scars from Caesarean section (CS), which in this study was the primary operation in 90% of the patients, produced the highest incidence of incisional hernia. Adesunkanmi [19] in Ile-Ife made similar observations and noted that the patients' age, parity and indication for sectioning did not influence the development of the hernias.

Our patients were in their prime economic and reproductive ages; this carries implications on their economic productivity, quality of life [20] and subsequent pregnancies. Many were scared of developing serious obstetric emergency. [21] Many erroneously linked the hernia to pregnancies and were indeed scared of carrying another pregnancy with the hernia in place. Their primary complaint was a loss of form particularly during pregnancy and this had a profound psychological effect on them. Four repairs were undertaken immediately after elective Caesarean sections; this practice carries the dreaded risk of mesh infection but we were compelled into instituting the repairs primarily to avoid the complications of multiply exposing these patients to general anaesthesia, minimize the cost of surgery and most importantly, losing the patients to care after delivery only to re-appear with a larger and more complex hernia with the next pregnancy. These set of patients received combination intravenous post-operative antibiotics to reduce the risk of infection.

That most patients in our series presented with recurrent hernias within six months of a previous suture repair strongly suggests technical failure of such repairs; late recurrence occurs at five years and is usually caused by defective healing. [3],[22],[23] Suture repair of incisional hernia is still practiced [24] but often leads to fascial tension with the suture eventually cutting through the fascia and ultimately leading to recurrence rates of 30-50%. It was our observation that all the failed repairs did not show evidence of having dissected and employing the fascial layer. Adequate repair of incisional hernia requires dissecting out the ugly scar and redundant tissue, the sac where present and also identifying the healthy fascial margins which is used in the repair. We routinely open the peritoneum in our practice even in patients without features of intestinal obstruction because we had previously found many patients to harbour adhesions. These processes are usually bloody and technically difficult particularly in recurrent hernias.

Advocacy for synthetic mesh repair of abdominal wall hernias is based on its low recurrence rate when compared with suture repair. The mesh provokes an intense inflammatory reaction, the extent of which depends on the amount and structure of mesh inserted. 25 The inflammatory processes lead to invasion of its pores by fibroblasts, culminating in the laying down of collagen which forms a sheet of scar tissue that integrates the substance of the mesh and reinforce the abdominal wall. Polypropylene mesh has been used longest; it is cheaper than other available synthetic prosthesis, porous, semi-rigid and gets incorporated into surrounding fascia by fibroblast infiltration of the pores. It has a low infective potential, good stability and elasticity. Ammar et al.,26 reported more than 90% repair rate using mesh. Mesh placement may be on-lay or sub-lay; with the latter being technically difficult but more effective with a lower complication and recurrence rate. 27

Complications with mesh repair include seroma collection, wound/mesh infection, recurrence, stitch sinus and chronic pain. Seroma collection was the commonest complication encountered in our series; it is partly due to the intense inflammatory response to the presence of the mesh in the tissues as well as the extent of subcutaneous tissue dissection to raise skin flaps. 28 We observed the seroma tended to be more in volume and of prolonged duration when the dissection of the subcutaneous tissue was done with electrocautery. We routinely drained the wounds for 72 hours while further collections were aseptically aspirated. Vacuum-assisted closure devices are potentially promising in managing seroma in patients at high risk of this complication. 29

The cases of stitch sinuses resolved without active management. We recorded a 10.5% recurrence rate similar to figures reported in other studies; one recurrence occurred in a patient who received composite mesh which is not recommended for on-lay hernia repair. We did not record any incidence of wound or mesh infection. Infection of the mesh is dreaded and is more likely if the repair is done alongside an intra-abdominal surgery 30 and may require removal of the mesh; adherence to surgical principles and prophylaxis adequately eliminates this complication.


   Conclusion Top


Midline Caesarean section is the commonest cause of incisional hernia in our practice, with many patients' further developing recurrences from failed repairs. Open prosthetic repair of these hernias with polypropylene mesh is strongly advocated as it carries a low risk of post operative morbidity and leads to good patient satisfaction in two years. We encourage its adoption as a standard for repairing these hernias in Nigeria.

 
   References Top

1.Skipworth JR, Khan Y, Motson RW, Arulampalam TH, Engledow AH. Incisional hernia rates following laparoscopic colorectal resection. Int J Surg 2010;8:470-3.  Back to cited text no. 1
    
2.Javid PJ, Brooks DC. Hernias. In: Zinner M, Ashley S, editors. Maingot's Abdominal Operations. 11 th ed. New York: McGraw Hill; 2007. p. 103-139.  Back to cited text no. 2
    
3.Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, IJzermans JN, et al. A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 2000;343:392-8.  Back to cited text no. 3
    
4.Chugulu S, Kihunwa A. Preliminary results on polypropylene mesh use for abdominal hernia repairs- The experience at KCMC-Moshi, Tanzania, 2001. Arch Surg 2009;144:740-5.  Back to cited text no. 4
    
5.Agbakwuru EA, Olabanji J, Alatise O, Okwerekwu R, Esimai O. Incisional hernia in women: Predisposing factors and management where mesh is not readily available. Libyan J Med 2009;4:66-9.  Back to cited text no. 5
    
6.Adotey JM. Incisional hernia: A review. Niger J Med 2006;15:34-43.  Back to cited text no. 6
[PUBMED]    
7.Dur AH, den Hartog D, Tuinebreijer WE, Kreis RW, Lange JF. Low recurrence rate of a two-layered closure repair for primary and recurrent midline incisional hernia without mesh. Hernia 2009;13:421-6.  Back to cited text no. 7
    
8.Kingsnorth A, Leblanc K. Management of Abdominal Hernias. 3 rd ed. London: Arnold; 2003. p. 262-279.  Back to cited text no. 8
    
9.Bikhchandani J, Fitzgibbons RJ Jr. Repair of giant ventral hernias. Adv Surg 2013;47:1-27.  Back to cited text no. 9
    
10.Pilay Y, Naidoo N, Madiba T. Incisional hernia: Experience in a single surgical unit. East Cent Afr J Surg 2006;12:42-6.  Back to cited text no. 10
    
11.Memon W, Khanzada T, Samad A, Kumar B. Incisional hernia repair with polypropylene mesh. JPMI 2009;23:159-63.  Back to cited text no. 11
    
12.Pavan BM, Gurukiram CS, Mahesh SH, Raveesh PM, Venkatesh NS, Shivkumarappa GM. Prospective study for assessment of incisional hernia and its outcome following anatomical repair and polypropylene mesh repair. Int J Biol Med Res 2013;4:3472-4.  Back to cited text no. 12
    
13.Adesunkanmi AR, Faleyimu B. Incidence and aetiological factors of incisional hernia in post-caeserian operations in a Nigerian hospital. J Obstet Gynaecol 2003;23:258-60.  Back to cited text no. 13
    
14.Poelman MM, Schellekens JF, Langenhorst BL, Schreurs WH. Health-related quality of life in patients treated for incisional hernia with onlay technique. Hernia 2010;14:237-42.  Back to cited text no. 14
    
15.Rao RS, Shankaregowda HS. A case of herniated gravid uterus through a laparotomy scar. Indian J Med Sci 2006;60:154-7.  Back to cited text no. 15
[PUBMED]  Medknow Journal  
16.Franz MG. The biology of hernias and the abdominal wall. Hernia 2006;10:462-71.  Back to cited text no. 16
[PUBMED]    
17.Klinge U, Binnebosel M, Mertens PR. Are collagens the culprits in the development of incisional and inguinal hernias? Hernia 2006;10:472-7.  Back to cited text no. 17
    
18.Schumpellck V, Klinge U, Junge K, Stumpf M. Incisional abdominal hernia: The open mesh repair. Langenbecks Arch Surg 2004;389:1-5.  Back to cited text no. 18
    
19.Ladurner R, Chiapponi C, Linhuber Q, Mussack T. Long term outcome and quality of life after open incisional hernia repair- Light versus heavy weight meshes. BMC Surg 2011;11:25.  Back to cited text no. 19
    
20.Ammar S, Ismail T. Abdominal wall hernias in upper Egypt: A different spectrum. East Cent Afr J Surg 2008;13:109-13.  Back to cited text no. 20
    
21.McLanahan D, King L, Weems C, Novotney M, Gibson K. Retrorectus prosthetic mesh repair of midline abdominal hernia. Am J Surg 1997;173:445-9.  Back to cited text no. 21
    
22.Kaya B, Uctum Y, Eris C, Bat O, Ziyade S, Kutanis R. The surgical results of onlay mesh repair for incisional hernia. J Clin Anal Med 2012;3:425-8.  Back to cited text no. 22
    
23.Lopez-Cano M, Armengol-Carrasco M. Use of vacuum-assisted closure in open incisional hernia repair: A novel approach to prevent seroma formation. Hernia 2013;17:129-31.  Back to cited text no. 23
    
24.Vannelli A, Battaglia L, Poiasina E, Corsi C, Conte C, Fiore F, et al. A tension-free technique for repair of large incisional hernias during abdominal surgery. S Afr J Surg 2008;46:112-5.  Back to cited text no. 24
    


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1]


This article has been cited by
1 A systematic review of outcome reporting in incisional hernia surgery
D Harji,C Thomas,S A Antoniou,H Chandraratan,B Griffiths,B T Henniford,L Horgan,F Köckerling,M López-Cano,L Massey,M Miserez,A Montgomery,F Muysoms,B K Poulose,W Reinpold,N Smart
BJS Open. 2021; 5(2)
[Pubmed] | [DOI]
2 Large Post-Surgical Incisional Hernias: Case Reports and a Review of Barriers Against Early Presentation and Refusal to Consent to Surgery
Friday Emeakpor Ogbetere
African Journal of Biology and Medical Research. 2021; 4(2): 19
[Pubmed] | [DOI]
3 Use of commercial mesh for hernia repair in a low resource setting: experience after 500 cases
E. A. Agbakwuru,O. Olasehinde,C. I. Onyeze,A. C. Etonyeaku,A. O. Mosanya,F. O. Wuraola,A. A. Akinkuolie,A. A. Aderounmu,A. O. Adisa
Hernia. 2019;
[Pubmed] | [DOI]
4 A systematic analysis highlighting deficiencies in reported outcomes for patients with stage IV colorectal cancer undergoing palliative resection of the primary tumour
Deena P. Harji,Abigail Vallance,Jenny Selgimann,Simon Bach,Faheez Mohamed,Julia Brown,Nicola Fearnhead
European Journal of Surgical Oncology. 2018;
[Pubmed] | [DOI]



 

Top
  
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Patients and methods
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed4831    
    Printed194    
    Emailed0    
    PDF Downloaded119    
    Comments [Add]    
    Cited by others 4    

Recommend this journal